- ISO 1133
- ASTM D1238
Automated Melt Flow Index Tester / Semi Auto Melt Indexer | 521-4A
Toyo Seiki · Melt Flow Index (MFR, MVR) / Melt Viscosity
The Semi Auto Melt Flow Indexer is designed for measuring of the MFR (melt mass-flow rate) and MVR (melt volume-flow rate) according to ISO 1133 and ASTM D1238 with semi-automated functions such as loading test weight, residue purging and assisted cylinder cleaning to reduce the burden during operation, ensure operation safety and shortening work time.
เอกสารดาวน์โหลด
ข้อมูลจำเพาะ
| ISO 1133 | Plastics-Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics |
|---|---|
| ASTM D1238 | Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer |
| Model | 4A |
| Test temperature | Max. 350°C(400°C optional) |
| Test load | • 0.325kg, 2.160kg, 5.000kg (standard) / • 1.000kg, 1.050kg, 1.200kg, 3.800kg, 10.000kg, 12.500kg, 21.600kg (optional) |
| Type of test | • Procedure B (MVR/MFR): Automatic measurement / • Procedure A (MFR): Manual* measurement (*automatic measurement is available as an option) |
| Sample filling | Manual operation |
| Weight lifting | Automatic |
| Die plug* opening | Automatic (*die plug is option) |
| Residue purging | Automatic |
| Cylinder cleaning | Automatic*(*except setting & disposal of cleaning gauze) |
| Piston cleaning | Manual operation |
| Die cleaning | Manual operation |
| Options | Automatic cutting device, Die plug, Strand collection device, Procedure A automation, Testing software, High temperature option |
| Electrical | Single-phase, AC100V, 50/60Hz, 1.5kVA (or speficy) |
| Compressed air | 0.6MPa |
| Dimensions | W740 × D605 × H*1100 to 1180mm(*level adjustment) |
| Net weight | Approx. 150kg* / *except test load & option |
ตารางเปรียบเทียบรุ่น
| Item | Value |
|---|---|
| ISO 1133 | Plastics-Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics |
| ASTM D1238 | Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer |
เลื่อนตารางไปทางข้างเพื่อดูทุกคอลัมน์
| Item | Value |
|---|---|
| Model | 4A |
| Test temperature | Max. 350°C(400°C optional) |
| Test load | • 0.325kg, 2.160kg, 5.000kg (standard) / • 1.000kg, 1.050kg, 1.200kg, 3.800kg, 10.000kg, 12.500kg, 21.600kg (optional) |
| Type of test | • Procedure B (MVR/MFR): Automatic measurement / • Procedure A (MFR): Manual* measurement (*automatic measurement is available as an option) |
| Sample filling | Manual operation |
| Weight lifting | Automatic |
| Die plug* opening | Automatic (*die plug is option) |
| Residue purging | Automatic |
| Cylinder cleaning | Automatic*(*except setting & disposal of cleaning gauze) |
| Piston cleaning | Manual operation |
| Die cleaning | Manual operation |
| Options | Automatic cutting device, Die plug, Strand collection device, Procedure A automation, Testing software, High temperature option |
| Electrical | Single-phase, AC100V, 50/60Hz, 1.5kVA (or speficy) |
| Compressed air | 0.6MPa |
| Dimensions | W740 × D605 × H*1100 to 1180mm(*level adjustment) |
| Net weight | Approx. 150kg* / *except test load & option |
เลื่อนตารางไปทางข้างเพื่อดูทุกคอลัมน์