TH
  • ISO 13145
  • ISO 6502
  • ASTM D5289
  • ASTM D6204
  • ASTM D6601
  • ASTM D6048
  • ASTM D7050
  • ASTM D7605
  • ASTM D8059
  • DIN 53529

MDR 3000 Professional Moving Die Rheometer

ModelMDR 3000 Professional

MonTech · Moving Die Rheometer

Entry model instrument in the Rubber Process Analyzer (RPA) technology. The MDR 3000 Prof. can be operated either in static testing mode (MDR) or also in dynamic testing mode (RPA).

Datasheets

Specification

International standardsISO 13145, ISO 6502, ASTM D 5289, ASTM D 6204, ASTM D 6601, ASTM D 6048, ASTM D 7050, ASTM D 7605, ASTM D 8059, DIN 53529, ...
Die configurationBiconical, closed die system, sealed
Drive systemDirect, wearless servo drive system with ceramic bearings
Oscillation frequency0.001 Hz to 33 Hz (0.001 Hz to 50 Hz optional) (0.05 to 2000 cpm (0.05 to 3000 cpm))
Oscillation strain+/- 0.01° to 20° (+/- 0.01° to 90° optional) (+/- 0.14% to 280% (0.14% to 1260%))
Temperature rangeAmbient to 232 °C
Measured DataTorque (dNm, lbf.in, kgf.cm), Shear modulus (Pa, dynes/cm², psi), Dynamic viscosity (Pa s), Temperature (°C, °F), Pressure (bar, kg per cm²), Time (min - min / min - sec / sec), Frequency (Hz, cpm), Shear rate (1/s, rad/s), Strain (deg, %), Cure rate (1/min, 1/sec)
Calculated DataS΄, S˝, S * , G΄, G˝, G * , tan δ, phase angle, cure rate, η΄, η˝, η * , ...
Die gap0.45 mm nominal
Sample volumeapprox. 4.5 cm³
Closing systemSoft closing to prevent film tearing and damage of test sample
Torque range0.001 to 250 dNm
Temperature control systemAmbient to 232 °C, precision +/- 0.03 °C, Max. heating and cooling rate: 85°C/min, digital, microprocessor controlled (Pneumatic double channel cooling system optional)
Temperature check systemRecordings of the temperature gradient on the screen, microprocessor monitored
SubroutinesIsothermal, Non-Isothermal, Timed, Temperature Sweep, Strain Sweep, Frequency Sweep, Shear rate Sweep, Relaxation, Retardation, Hysteresis, Tension tests, LAOS, ...
Data InterfaceEthernet (10/100 MBit), USB (int.), CF card (int.), RS232 (opt.)
Data pointsOver 3500 data points available for each static subtest Including: S‘ Min, S‘ Max, TS 1, TS 2, TC 10, TC 30, TC 50, TC 90 Integrated, automatic reporting features for dynamic tests
Pneumaticsmin. 4.5 Bar / 60 psi
Electrical200-240 V, 6 Amps, 47-63 Hz, Single phase
Instrument options- Instrument control panel with 5" touchscreen display and printer - Adapted transducers for high or low-viscosity torque range - Normal force / Pressure measurement - Double channel forced air cooling system - Low-temperature cooling system MCool 10 /MCool -40 - Extended thermal range to +300°C - Autoloader 5 or 10 sample linear - Autoloader with 24, 48 or 100 sample tray or tray changers - R-VS 3000 constant volume sample cutter
Normal force / Pressure (opt.)0 to 10.000 kPa (1.450 lbin), Auto tare

Model comparison

MonTech Moving Die Rheometers and Rubber Process Analyzers - range comparison (pp. 20-21; MDR 3000 Basic / MDR 3000 = static testing, MDR 3000 Professional / D-MDR 3000 / D-RPA 3000 = static and dynamic testing)
MDR 3000 BasicMDR 3000MDR 3000 ProfessionalD-MDR 3000D-RPA 3000
Instrument descriptionCompact, entry model instrument for repetitive quality control testing as well as simple R&D applicationsHigh-end instrument for QC and static R&D testing for a broad range of materials (from LSR, all kinds of elastomers to composite materials)Entry model instrument in the Rubber Process Analyzer (RPA) technology. The MDR 3000 Prof. can be operated either in static testing mode (MDR) or also in dynamic testing mode (RPA).Top model for advanced dynamic testing of all kinds of rubber, rubber-like, curing or crosslinking materials. This includes TPE, TPV, LSR, Composite materials, Polyolefins, ...High-end instrument for demanding static and dynamic testing in QC and R&D with a huge set of customizing options. This enables testing capabilities that have not been possible to measure in a Rheometer before, such as die gap regulation, High-speed data acquisition, FT-Rheology, low-temperature cooling, …
International standardsISO 6502, ASTM D 5289, DIN 53529ISO 6502, ASTM D 5289, DIN 53529ISO 13145, ISO 6502, ASTM D 5289, ASTM D 6204, ASTM D 6601, ASTM D 6048, ASTM D 7050, ASTM D 7605, ASTM D 8059, DIN 53529ISO 13145, ISO 6502, ASTM D 5289, ASTM D 6204, ASTM D 6601, ASTM D 6048, ASTM D 7050, ASTM D 7605, ASTM D 8059, DIN 53529ISO 13145, ISO 6502, ASTM D 5289, ASTM D 6204, ASTM D 6601, ASTM D 6048, ASTM D 7050, ASTM D 7605, ASTM D 8059, DIN 53529
Die configurationBiconical, closed die system, sealedBiconical, closed die system, sealedBiconical, closed die system, sealedBiconical, closed die system, sealedBiconical, closed die system, sealed
Drive systemMechanical, brushless DC eccentric driveDirect, wearless servo drive systemDirect, wearless servo drive system with ceramic bearingsDirect, wearless servo drive system with ceramic bearingsAdvanced wearless servo drive system with ceramic bearings
Oscillation frequency1.667 Hz1.667 Hz0.001 Hz to 33 Hz (0.001 Hz to 50 Hz optional)0.001 Hz to 100 Hz0.001 Hz to 100 Hz
Oscillation strain+/- 0.1°, 0.2°, 0.5°, 1°, 3° or 7.17° Mechanically adjustable+/- 0.01° to 5° Programmable via Software+/- 0.01° to 20° (+/- 0.01° to 90° optional)+/- 0.001° to 180°+/- 0.0001° to 360°
Temperature rangeAmbient to 232 °CAmbient to 232 °CAmbient to 232 °CAmbient to 232 °CAmbient to 232 °C
Measured DataTorque, temperature, frequency / Optional: Normal forceTorque, temperature, frequency, strain / Optional: Normal forceTorque, temperature, frequency, strain / Optional: Normal forceTorque, temperature, frequency, strain / Optional: Normal forceTorque, temperature, frequency, strain / Optional: Normal force, die gap, die pressure
Calculated DataS΄, S˝, S *, tan δS΄, S˝, S *, tan δS΄, S˝, S *, G΄, G˝, G *, tan δ, η΄, η˝ and η*S΄, S˝, S *, G΄, G˝, G *, tan δ, η΄, η˝ and η*S΄, S˝, S *, G΄, G˝, G *, tan δ, η΄, η˝ and η*

Scroll the table sideways for every column