EN
  • ISO 1183-1
  • ISO 1817
  • ISO 2781
  • ASTM D297
  • ASTM D792

Semi-Automatic Density Tester for Plastics and Rubber / Automatic Densimeter | 265-DSG-2

รุ่นNo. 265

Toyo Seiki · Thickness / Hardness / Density

This high precision digital densimeter for polymers or plastics is ideal for almost any laboratory environment. ● Automatic Weighing : The weighing operation is fully automatic, and the density is calculated and displayed on the screen. ● Versatile : It can measure the density of solids, liquids, and even the rate of volume change.

เอกสารดาวน์โหลด

ข้อมูลจำเพาะ

ISO 1183-1Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pycnometer method and titration method
ISO 2781Rubber, vulcanized or thermoplastic — Determination of density
ASTM D792Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
ModelDSG-2
Measurement methodImmersion / hydrostatic weighing
Capacity100g
Calibration weightBuilt-in
Resolution0.00001g (0.01mg) / 0.000001g/cm3
Operation panel4.7 in LCD touch screen
Dipping speed10, 20, 30mm/s (variable)
Data savingMax. 1000 data
Output interfacesUSB (x1), RS232C (x1, for small printer)
Electrical• Single-phase, AC100-240V, 50/60Hz, 0.1kVA (Main unit) / • Single-phase, AC100-240V, 50/60Hz, 0.1kVA (Balance unit)
DimensionsW290 × D443 × H900mm (including balance unit)
Net weight (approx.)35kg (including balance unit)
Scope of delivery• DSG-2 main unit / • Balance unit / • Standard beaker / • Sample clamps (pierce x1, ohm x3)
Options• Various sample clamps / • Automatic correction of water/air density (temperature sensor) / • Double-wall beaker for constant temperature water supply (note: external chiller is required) / • Volume change measurement (add-on program) / • Expansion ratio measurement (add-on program) / • Liquid density measurement (add-on program, glass ball clamp and small beaker) / • Data export software / • Small thermal printer / • Calibration certificate with traceability

ตารางเปรียบเทียบรุ่น

ItemValue
ISO 1183-1Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pycnometer method and titration method
ISO 2781Rubber, vulcanized or thermoplastic — Determination of density
ASTM D792Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement

เลื่อนตารางไปทางข้างเพื่อดูทุกคอลัมน์

Specifications
ItemValue
ModelDSG-2
Measurement methodImmersion / hydrostatic weighing
Capacity100g
Calibration weightBuilt-in
Resolution0.00001g (0.01mg) / 0.000001g/cm3
Operation panel4.7 in LCD touch screen
Dipping speed10, 20, 30mm/s (variable)
Data savingMax. 1000 data
Output interfacesUSB (x1), RS232C (x1, for small printer)
Electrical• Single-phase, AC100-240V, 50/60Hz, 0.1kVA (Main unit) / • Single-phase, AC100-240V, 50/60Hz, 0.1kVA (Balance unit)
DimensionsW290 × D443 × H900mm (including balance unit)
Net weight (approx.)35kg (including balance unit)
Scope of delivery• DSG-2 main unit / • Balance unit / • Standard beaker / • Sample clamps (pierce x1, ohm x3)
Options• Various sample clamps / • Automatic correction of water/air density (temperature sensor) / • Double-wall beaker for constant temperature water supply (note: external chiller is required) / • Volume change measurement (add-on program) / • Expansion ratio measurement (add-on program) / • Liquid density measurement (add-on program, glass ball clamp and small beaker) / • Data export software / • Small thermal printer / • Calibration certificate with traceability

เลื่อนตารางไปทางข้างเพื่อดูทุกคอลัมน์

วิดีโอ