TH
  • ISO 37

Fully-Automated Rubber Tensile Testing Machine / Strograph™ AR-T | 119

ModelNo. 119

Toyo Seiki · Tensile / Compression / 3-Point Bend / Peel

The Strograph AR-T is a testing machine for fully automatic tensile testing of rubber specimens under temperatures ranging from -40°C to 150°C. It consists of a specimen magazine (ISO 37 Dumb-bell test piece Type 1A), specimen dimension measuring unit, specimen feeding mechanism, pneumatic grips, measuring unit, extensometer, broken specimen removal unit, constant temperature chamber, refrigerator, and PC.

Specification

ISO 37Rubber, vulcanized or thermoplastic- Determination of tensile stress-strain properties
ModelAR-T
Load capacityMax. 1kN
Test speed range0.5 to 500mm/min.
Effective crosshead travelApprox. 700mm
Thickness gaugeMeasurement point: 3 points / Anvil: ∅5mm
ExtensometerNon-contact type / Gauge length: 20mm
Specimen feederMax. 120 specimens (n=6 specimens × 20 trays)
Temperature range-40°C to 150°C
Safeguards• Rod type limitter / • Emergency stop swtich
Power supply• Main unit: Three-phase, AC200V, 50/60Hz, 6.9kVA (or specify) / • PC: Single-phase, AC100V, 50/60Hz, 0.5kVA / • Specimen feeder: Single-phase, AC100V, 50/60Hz, 1.0kVA / • Chamber: Three-phase, AC200V, 50/60Hz, 13.8kVA (or specify) / • Extensometer: Single-phase, AC100V, 50/60Hz, 0.5kVA
Compressed air• 0.5MPa, 40L/min. (For specimen feeder) / • 0.5MPa, 150L/min. (For chamber)
Cooling water0.2MPa to 0.8MPa, 30L/mmin. to 40L/min., 30°C or less
Dimensions• Main unit: W2200 × D1560 × H2030mm / • Refrigerator: W1000 × D1100 × H1530mm

Model comparison

ItemValue
ISO 37Rubber, vulcanized or thermoplastic- Determination of tensile stress-strain properties

Scroll the table sideways for every column

ItemValue
ModelAR-T
Load capacityMax. 1kN
Test speed range0.5 to 500mm/min.
Effective crosshead travelApprox. 700mm
Thickness gaugeMeasurement point: 3 points / Anvil: ∅5mm
ExtensometerNon-contact type / Gauge length: 20mm
Specimen feederMax. 120 specimens (n=6 specimens × 20 trays)
Temperature range-40°C to 150°C
Safeguards• Rod type limitter / • Emergency stop swtich
Power supply• Main unit: Three-phase, AC200V, 50/60Hz, 6.9kVA (or specify) / • PC: Single-phase, AC100V, 50/60Hz, 0.5kVA / • Specimen feeder: Single-phase, AC100V, 50/60Hz, 1.0kVA / • Chamber: Three-phase, AC200V, 50/60Hz, 13.8kVA (or specify) / • Extensometer: Single-phase, AC100V, 50/60Hz, 0.5kVA
Compressed air• 0.5MPa, 40L/min. (For specimen feeder) / • 0.5MPa, 150L/min. (For chamber)
Cooling water0.2MPa to 0.8MPa, 30L/mmin. to 40L/min., 30°C or less
Dimensions• Main unit: W2200 × D1560 × H2030mm / • Refrigerator: W1000 × D1100 × H1530mm

Scroll the table sideways for every column