- ISO 6988
- ISO 3231
- DIN 50018
- ASTM G87-02
- IEC 60950
- IEC 60068-2-42
- IEC 60068-2-60
Walk In Mixed Noxious Gas Chamber
LIB · Walk-in & Drive-in Chambers
Engineered for Large-Scale Corrosion Reliability Testing The LIB industry Walk-In Mixed Gas Test Chamber is designed to reproduce highly corrosive industrial and atmospheric environments using controlled concentrations of sulfur dioxide (SO₂), hydrogen sulfide (H₂S), nitrogen dioxide (NO₂), chlorine (Cl₂), and other mixed gases. Unlike conventional small-volume gas corrosion chambers, this walk-in design allows full-scale testing of: EV battery systems, Automotive assemblies, Aerospace components, Communication cabinets, Power distribution equipment, PCB systems,Military electronics,Rail trans
Datasheets
- Lib Industry Walk In Chamberlib-industry-walk-in-chamber.pdfDownload PDF
- User Manual For So2 Gas Corrosion Chamberuser-manual-for-so2-gas-corrosion-chamber.pdfDownload PDF
Specification
| Custom Capacity | Up to 120 m³ for large systems, vehicles, radar equipment, and military applications |
|---|---|
| Supported Gases | H₂S, SO₂, NO₂, Cl₂ |
| Gas Mixing Mode | Single gas, binary, ternary, or four-component mixed gas testing |
| Gas Concentration Range | 0.1 ppm ~ 200 ppm (Expandable to 500 ppm) |
| Temperature Range | +15°C ~ +60°C (Optional up to +85°C) |
| Temperature Stability | ≤ ±0.5°C |
| Temperature Uniformity | ≤ ±1.0°C |
| Humidity Range | 60% ~ 95% RH |
| Humidity Deviation | ≤ ±3.0% RH |
| MFC Control Accuracy | ±1.0% F.S. |
| System Concentration Accuracy | ≤ ±5.0% F.S. |
| Explosion Protection | Ex d ib IIB T4 Gb or customized higher protection level |
| Safety Protection | Leakage, over-temperature, low-water, gas interruption protection |
| Exhaust Treatment System | Multi-stage chemical scrubber with activated carbon adsorption system |